Product information
Overview
-
This test is conducted during mass production inspection to verify the power level at which a tag responds by varying the power at a fixed frequency. The measurement is performed on test points where the communication scenario is set to "Sens." Each test point requires 5 ms, and the detected response points (dBm) are recorded in the log. The flow of the sensitivity test, from start to finish, is illustrated on the following pages. Please refer to them for details.

Feature
-
Easy setup with using just a mouse
-
Sensitivity testing can be conducted simultaneously with reading tests and pointing tests. *Test results must be viewed on a separate screen.

-
In RFID manufacturing, tag response power can be measured at high speed
-
Variations within user-defined threshold values in specified frequency bands can be easily visualized.

Specification
|
|
Test Name
|
Sensitivity Test
|
Frequency Range
|
800MHz~1300MHz, 1MHz Step
|
Variance Inside Control Limits
|
Maximum:+15dBm
Minimum:-25dBm, 0.25dBm Step |
Communication Scenario
|
Sens
|
Number of test points
|
31points (Include point test and read test)
|
Testing time per point
|
1point: 5ms
|
Output test files
|
Tested logs(SQLite , XLSX or CSV)
|
Operation mode
|
Remote(DIO)
|